Analytical instruments
Wall-mounted Silver Sulfide Ion Analyzer
Product Introduction
The online silver sulfide ion analyzer is a precision instrument mainly used to detect silver sulfide ions in liquids. There is a silver sulfide ion selective membrane at the front end of the sensor. When the sensor is placed in the measured solution, the silver sulfide ions in the measured solution enter the interior of the sensor through the selective membrane. The cations inside the sensor increase and form a tiny potential difference with the reference electrode. The potential difference is proportional to the concentration of silver sulfide ions. The potential difference is amplified through the circuit to obtain the concentration of silver sulfide ions.
Wall-mounted Iodide Ion Analyzer
Product Introduction
The online iodide ion analyzer is a precision instrument mainly used to detect iodide ions in liquids. There is a layer of iodide ion selective membrane at the front end of the sensor. When the sensor is placed in the measured solution, iodide ions in the solution enter the interior of the sensor through the selective membrane. A tiny potential difference is formed inside the sensor between the cation and the reference electrode. The potential difference is positively proportional to the concentration of iodide ions. The potential difference is amplified by the circuit, so that the concentration of iodide ions can be obtained.
Wall-mounted Potassium Ion Analyzer
Product Introduction
The online potassium ion analyzer is a precision instrument mainly used to detect potassium ions in liquids. There is a potassium ion selective membrane at the front end of the sensor. When the sensor is placed in the measured solution, potassium ions in the measured solution enter the interior of the sensor through the selective membrane. The cation inside the sensor increases, forming a tiny potential difference with the reference electrode. The potential difference is positively proportional to the concentration of potassium ions. The potential difference is amplified through the circuit, so that the concentration of potassium ions can be obtained.
Product Introduction
TDS refers to the total dissolved solids. By applying a certain electromotive force (sinusoidal alternating current) across the electrodes, the ions dissolved in water are proportional to the generated current. The current is measured after digital amplification to calculate the total dissolved solids in the solution.
Wall-mounted Magnesium Ion Analyzer
Product Introduction
The online magnesium ion analyzer is a precision instrument mainly used to detect magnesium ions in liquids. There is a magnesium ion selective membrane at the front end of the sensor. When the sensor is placed in the measured solution, magnesium ions in the solution pass through the selective membrane into the interior of the sensor. A tiny potential difference is formed inside the sensor between the cations and the reference electrode. The potential difference is proportional to the concentration of magnesium ions. The potential difference is amplified through the circuit for processing, thereby obtaining the concentration of magnesium ions.
Wall-mounted Nitrite Ion/Nitrite Analyzer
Product Introduction
The online nitrite analyzer is a precision instrument mainly used to detect nitrite ions in liquids. There is a nitrite ion selective membrane at the front end of the sensor. When the sensor is placed in the measured solution, nitrite ions in the solution enter the interior of the sensor through the selective membrane. The cation inside the sensor rises and forms a tiny potential difference with the reference electrode. The magnitude of the potential difference is proportional to the concentration of nitrite ions. The potential difference is amplified and processed through a circuit, so as to obtain the concentration of nitrite ions.
Wall-mounted Nitrate Nitrogen Analyzer
Product Introduction
The online nitrate nitrogen analyzer is a precision instrument mainly used to detect nitrate nitrogen ions in liquids. There is a nitrate nitrogen ion selective membrane at the front end of the sensor. When the sensor is placed in the measured solution, nitrate nitrogen ions in the solution enter the inside of the sensor through the selective membrane. The cation concentration inside the sensor increases, forming a tiny potential difference with the reference electrode. The potential difference is proportional to the concentration of nitrate nitrogen ions. The potential difference is amplified by the circuit to obtain the concentration of nitrate nitrogen ions.
Wall-mounted Nitrate/Nitrite Analyzer
Product Introduction
The online nitrate analyzer is a precision instrument mainly used to detect nitrate ions in liquids. There is a nitrate ion selective membrane at the front end of the sensor. The sensor is placed in the test solution. Nitrate ions in the test solution enter the interior of the sensor through the selective membrane. The cation concentration inside the sensor increases, forming a tiny potential difference with the reference electrode. The potential difference is positively correlated with the concentration of nitrate ions. The circuit amplifies the potential difference to obtain the concentration of nitrate ions.
Wall-mounted Copper Ion Analyzer
Product Introduction
The online copper ion analyzer is a precision instrument mainly used to detect copper ions in liquids. There is a copper ion selective membrane at the front end of the sensor. When the sensor is placed in the measured solution, copper ions in the solution enter the interior of the sensor through the selective membrane. The cation concentration inside the sensor increases, forming a tiny potential difference with the reference electrode. The potential difference is proportional to the copper ion concentration. The potential difference is amplified through the circuit. Thus, the copper ion concentration is obtained.
Wall-mounted Fluoride Ion Analyzer
Product Introduction
The online fluoride ion analyzer is a precision instrument mainly used to detect fluoride ions in liquids. There is a layer of fluoride ion solid membrane at the front end of the sensor. The sensor is placed in the tested solution, and fluoride ions in the tested solution enter the interior of the sensor through the solid membrane. The cation concentration inside the sensor increases, forming a tiny potential difference with the reference electrode. The potential difference is proportional to the fluoride ion concentration. The potential difference is amplified through the circuit. Thus, the fluoride ion concentration is obtained.
Wall-mounted Chloride Ion Analyzer
Product IntroductionThe online chloride ion analyzer is a precision instrument mainly used to detect chloride ions in liquids. There is a layer of chloride ion solid membrane at the front end of the sensor. The sensor is placed in the measured solution, and the chloride ions in the measured solution enter the interior of the sensor through the solid membrane. The cation inside the sensor rises, forming a tiny potential difference with the reference electrode. The potential difference is proportional to the concentration of chloride ions. The potential difference is amplified by the circuit. Thus, the chloride ion concentration is obtained.